国产三级精品视频,特大黑人与亚洲娇小,久久亚洲免费视频,久久婷婷激情五月天

您好,歡迎進入北京樂氏聯(lián)創(chuàng)科技有限公司網(wǎng)站!
一鍵分享網(wǎng)站到:
產(chǎn)品列表

—— PROUCTS LIST

技術文章Article 當前位置:首頁 > 技術文章 > 露點溫度法測定氣體燃料中蒸汽含量的試驗方法

露點溫度法測定氣體燃料中蒸汽含量的試驗方法

點擊次數(shù):3767 發(fā)布時間:2009-06-04

標準號:D1142-95
標準全稱應該翻譯為:“露點溫度法測定氣體燃料中蒸汽含量的試驗方法”
ASTM D1142 - 95(2006) Standard Test Method for Water Vapor Content of Gaseous Fuels by Measurement of Dew-Point Temperature
Significance and Use

Generally, contracts governing the pipeline transmission of natural gas contain specifications 

limiting the maximum concentration of water vapor allowed. Excess water vapor can cause 

corrosive conditions, degrading pipelines and equipment. It can also condense and freeze or form

 methane hydrates causing blockages. Water-vapor content also affects the heating value of natural gas, thus influencing the quality of the gas. 

This test method permits the determination of water content of natural gas.

1. Scope
1.1 This test method covers the determination of the water vapor content of gaseous fuels by measurement of the dew-point temperature and the calculation therefrom of the water vapor content. Note 1Some gaseous 

fuels contain vapors of hydrocarbons or other components that easily condense into liquid and 

sometimes interfere with or mask the water dew point. When this occurs, it is sometimes very 

helpful to supplement the apparatus in with an optical attachment that uniformly illuminates the dew point mirror and also magnifies the condensate on the mirror. With this attachment it is possible, 

in some cases, to observe separate condensation points of water vapor, hydrocarbons, and 

glycolamines as well as ice points. However, if the dew point of the condensable hydrocarbons is 

higher than the water vapor dew point, when such hydrocarbons are present in large amounts, they 

may flood the mirror and obscure or wash off the water dew point. Best results in distinguishing 

multiple component dew points are obtained when they are not too closely spaced.
Note 2
Condensation of water vapor on the dew-point mirror may appear as liquid water at temperatures as low as 0 to 10F (18 to 23C). At lower

 temperatures an ice point rather than a water dew point likely will be observed. The minimum dew 

point of any vapor that can be observed is limited by the mechanical parts of the equipment. Mirror 

temperatures as low as 150F (100C) have been measured, using liquid nitrogen as the coolant 

with a thermocouple attached to the mirror, instead of a thermometer well. 

 

版權所有 © 2025 北京樂氏聯(lián)創(chuàng)科技有限公司

總流量:989472  管理登陸  技術支持:化工儀器網(wǎng)  GoogleSitemap

ICP備案號:京ICP備06061264號-2
嘉祥县| 龙江县| 仁寿县| 昭觉县| 库尔勒市| 城口县| 望奎县| 西峡县| 松潘县| 安丘市| 西安市| 滁州市| 通山县| 荣昌县| 清镇市| 武山县| 兰考县| 肥城市| 龙州县| 仁寿县| 习水县| 邵阳县| 邹平县| 长兴县| 平定县| 四子王旗| 贵德县| 上思县| 南康市| 陈巴尔虎旗| 德保县| 安新县| 和硕县| 淅川县| 论坛| 东阿县| 富蕴县| 曲沃县| 贵阳市| 吐鲁番市| 东乡族自治县|